CVE Vendors Products Updated CVSS v3.1
CVE-2026-104739 2 Rabilal, Wordpress-extensions 2 Js Help Desk – Ai-powered Support & Ticketing System, Js Help Desk 2026-11-10 4.9 Medium
The JS Help Desk – AI-Powered Support & Ticketing System plugin for WordPress is vulnerable to arbitrary file deletion due to insufficient file path validation in the setSupportCustomImage function in all versions up to, and including, 5.0.1. This makes it possible for authenticated attackers, with administrator-level access and above, to delete arbitrary files on the server, which can easily lead to remote code execution when the right file is deleted (such as wp-config.php). Exploitation requires a two-step sequence: an administrator first saves a traversal-crafted value in the support_custom_img configuration field, then triggers deletion by uploading a new support custom image, at which point setSupportCustomImage() resolves and deletes the attacker-controlled path.
CVE-2026-54861 2 Aguilatechnologies, Wordpress-extensions 2 Wp Customer Area, Wp Customer Area 2026-11-10 7.1 High
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Aguila Technologies WP Customer Area customer-area allows Reflected XSS.This issue affects WP Customer Area: from n/a through 8.4.1.
CVE-2026-118046 2 Rabilal, Wordpress-extensions 2 Js Help Desk – Ai-powered Support & Ticketing System, Js Help Desk 2026-11-10 6.4 Medium
The JS Help Desk – AI-Powered Support & Ticketing System plugin for WordPress is vulnerable to Stored DOM-Based Cross-Site Scripting via the 'jsticket_message' parameter in all versions up to, and including, 5.0.2 due to insufficient input sanitization and output escaping. This makes it possible for authenticated attackers, with subscriber-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page. The payload fires specifically when an administrator or agent opens the affected ticket and the page initializes VenoBox, which reads the browser-decoded data-title attribute and passes it to jQuery .html(), making routine ticket review the trigger condition.
CVE-2026-120540 2 Iubenda, Wordpress-extensions 2 Iubenda, Iubenda 2026-11-10 7.2 High
The iubenda | All-in-one Compliance for GDPR / CCPA Cookie Consent + more plugin for WordPress is vulnerable to Stored Cross-Site Scripting in versions up to, and including, 3.13.6. This is due to the way iubendaParser::parse_comments() re-processes HTML inside IUB-COOKIE-BLOCK markers through the bundled simple_html_dom parser after WordPress has already KSES-filtered the saved comment: simple_html_dom's remove_noise() stores <code> bodies under a deterministic key ('___noise___ 1000') and restore_noise() later substitutes any matching substring back into attribute values WITHOUT re-escaping, allowing a quote-breaking payload stashed in an allowed <code> element to be injected into an allowed <abbr title="___noise___ 1000"> attribute at render time. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page, after an administrator approves the first (otherwise moderated) comment under WordPress's default comment_previously_approved setting.
CVE-2026-12266 1 Zohocorp 1 Ddi Central 2026-11-10 7.6 High
Zoho Corporation ManageEngine DDI Central versions 6200 and below are vulnerable to LDAP bind password exposure through insufficiently protected LDAP settings API.
CVE-2026-12265 1 Zohocorp 1 Ddi Central 2026-11-10 8.8 High
Zoho Corporation ManageEngine DDI Central versions 6200 and below are vulnerable to insufficient access control in HA failover endpoint leading to destructive PostgreSQL database operations.
CVE-2026-12264 1 Zohocorp 1 Ddi Central 2026-11-10 8.8 High
Zoho Corporation ManageEngine DDI Central versions 6200 and below are vulnerable to arbitrary file write via HA Failover Config sync upload leading to code execution as root.
CVE-2025-40759 2026-11-10 7.8 High
A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2025-40742 2026-11-10 5.3 Medium
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V11.0), SIPROTEC 5 6MD85 (CP300) (All versions < V11.0), SIPROTEC 5 6MD86 (CP300) (All versions < V11.0), SIPROTEC 5 6MD89 (CP300) (All versions < V11.0), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V11.0), SIPROTEC 5 6MU85 (CP300) (All versions < V11.0), SIPROTEC 5 7KE85 (CP300) (All versions < V11.0), SIPROTEC 5 7SA82 (CP100) (All versions < V8.91), SIPROTEC 5 7SA82 (CP150) (All versions < V11.0), SIPROTEC 5 7SA86 (CP300) (All versions < V11.0), SIPROTEC 5 7SA87 (CP300) (All versions < V11.0), SIPROTEC 5 7SD82 (CP100) (All versions < V8.91), SIPROTEC 5 7SD82 (CP150) (All versions < V11.0), SIPROTEC 5 7SD86 (CP300) (All versions < V11.0), SIPROTEC 5 7SD87 (CP300) (All versions < V11.0), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.91), SIPROTEC 5 7SJ81 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.91), SIPROTEC 5 7SJ82 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ85 (CP300) (All versions < V11.0), SIPROTEC 5 7SJ86 (CP300) (All versions < V11.0), SIPROTEC 5 7SK82 (CP100) (All versions < V8.91), SIPROTEC 5 7SK82 (CP150) (All versions < V11.0), SIPROTEC 5 7SK85 (CP300) (All versions < V11.0), SIPROTEC 5 7SL82 (CP100) (All versions < V8.91), SIPROTEC 5 7SL82 (CP150) (All versions < V11.0), SIPROTEC 5 7SL86 (CP300) (All versions < V11.0), SIPROTEC 5 7SL87 (CP300) (All versions < V11.0), SIPROTEC 5 7SS85 (CP300) (All versions < V11.0), SIPROTEC 5 7ST85 (CP300) (All versions < V11.0), SIPROTEC 5 7ST86 (CP300) (All versions < V11.0), SIPROTEC 5 7SX82 (CP150) (All versions < V11.0), SIPROTEC 5 7SX85 (CP300) (All versions < V11.0), SIPROTEC 5 7SY82 (CP150) (All versions < V11.0), SIPROTEC 5 7UM85 (CP300) (All versions < V11.0), SIPROTEC 5 7UT82 (CP100) (All versions < V8.91), SIPROTEC 5 7UT82 (CP150) (All versions < V11.0), SIPROTEC 5 7UT85 (CP300) (All versions < V11.0), SIPROTEC 5 7UT86 (CP300) (All versions < V11.0), SIPROTEC 5 7UT87 (CP300) (All versions < V11.0), SIPROTEC 5 7VE85 (CP300) (All versions < V11.0), SIPROTEC 5 7VK87 (CP300) (All versions < V11.0), SIPROTEC 5 7VU85 (CP300) (All versions < V11.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V11.0). The affected devices include session identifiers in URL requests for certain functionalities. This could allow an attacker to retrieve sensitive session data from browser history, logs, or other storage mechanisms, potentially leading to unauthorized access.
CVE-2024-54678 1 Siemens 13 Simatic Pcs Neo, Simatic S7-plcsim, Simatic Step 7 and 10 more 2026-11-10 8.2 High
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SIMOTION SCOUT TIA V5.7 (All versions < V20 Update 4), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2024-49849 2026-11-10 7.8 High
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions < V18 Update 6), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2026-12574 1 Zohocorp 1 Ddi Central 2026-11-10 8.1 High
Zoho Corporation ManageEngine DDI Central versions 6200 and below are vulnerable to Server-side HTML/JavaScript injection in analytics PDF generation leading to local file disclosure.
CVE-2026-12573 1 Zohocorp 1 Ddi Central 2026-11-10 8.8 High
Zoho Corporation ManageEngine DDI Central versions 6200 and below are vulnerable to Cisco IOS command injection via DHCP pool name leading to arbitrary commands on managed Cisco routers.
CVE-2026-123717 2026-11-10 N/A
OS command injection in the pass and bitwarden credential providers in Eclipse Foundation Eclipse Otterdog through 1.7.1 allows a user able to modify an organization configuration to execute arbitrary commands with the privileges of the operator running otterdog, including access to their credential vault, via a crafted secret reference (pass:<path> or bitwarden:<item>@<field>) or credential identifier that is resolved when otterdog apply is run.
CVE-2026-12572 1 Zohocorp 1 Ddi Central 2026-11-10 7.2 High
Zoho Corporation ManageEngine DDI Central version below 6201 is vulnerable to SQL injection in HA replication username handling leading to command execution as the PostgreSQL service account.
CVE-2026-95651 1 Zohocorp 1 Ddi Central 2026-11-10 7.5 High
Zoho Corporation ManageEngine DDI Central versions 6500 and below are vulnerable to an unauthenticated GSS-TSIG keytab update vulnerability in the Linux Node Agent.
CVE-2026-95646 1 Zohocorp 1 Ddi Central 2026-11-10 8 High
Zoho Corporation ManageEngine DDI Central versions 6500 and below are vulnerable to a Unicode-based command injection vulnerability in the Cisco IOS DHCP configuration functionality. This vulnerability could allow cluster-scoped operators to inject specially crafted Unicode characters, resulting in the execution of unintended device commands.
CVE-2026-119446 1 Nerves-hub 1 Nerves Hub Web 2026-11-10 N/A
Session Fixation vulnerability in the CLI login flow in nerves-hub nerves_hub_web allows an unauthenticated attacker to obtain an API token for another user's account via a crafted login link. Starting a CLI login with POST /api/auth/cli_session needs no authentication and returns a polling token, a confirmation URL that carries that token, and a confirmation code. When a signed-in user opens that URL and clicks Confirm, NervesHub.Accounts.verify_cli_session_token/2 creates an API token for the user's account and stores it on the login, and the next poll of GET /api/auth/cli_session/<token> returns it to whoever started the login. The confirmation code is only displayed and is never compared with anything, so it cannot show that the person confirming is the one who started the login. The confirm form carries a CSRF token and the page cannot be framed, so the attacker has to persuade the user to open the link and click the button themselves. This issue affects nerves_hub: from 2.5.0 before 2.5.3.
CVE-2026-120286 1 Nerves-hub 1 Nerves Hub Web 2026-11-10 N/A
Missing Authorization vulnerability in the device and deployment group pages in nerves-hub nerves_hub_web allows an authenticated organization member with the view role to change devices and deployment groups via LiveView events reserved for the manage role. The event handlers that add and delete device certificates, add and remove tags, overwrite or clear a device's manual location, remove a device from its deployment group, move matched devices into a deployment group or remove unmatched ones, import devices from a CSV, and start, retry or delete firmware delta builds carry out the change without calling authorized!/2, and the pages render the controls to every member. A view member can add a certificate that lets whoever holds its key connect as the device, delete a certificate so the device can no longer authenticate with it, and change which deployment group, and so which firmware release, a device receives. Everything stays within the organizations the member belongs to. This issue affects nerves_hub: from 1.0.0 before 2.5.3.
CVE-2026-120997 1 Nerves-hub 1 Nerves Hub Web 2026-11-10 N/A
Improper Session Invalidation vulnerability in the dashboard pages, device console and local shell channels in nerves-hub nerves_hub_web allows an organization member who is removed or given a lower role to keep acting at their old role through anything they had open at the time. The dashboard reads the member's role once when a page mounts, in the assign_org_to_scope hook of NervesHubWeb.Auth, and the console, local shell and device event stream channels check membership once at join. Removing a member or changing their role tells none of them, so open pages keep carrying out actions and open consoles keep running commands on the device until the page reloads or the socket disconnects. The dashboard also opens consoles over NervesHubWeb.UserSocket with a token that holds only the user's id, is accepted for 24 hours, and is not revoked by signing out, which disconnects only the session's LiveViews. Whoever holds a token taken from a page can open consoles as that user, within the user's current membership, until it expires. This issue affects nerves_hub: from 1.0.0 before 2.5.3.