| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The CS5000 Fire Panel is vulnerable due to a hard-coded password that
runs on a VNC server and is visible as a string in the binary
responsible for running VNC. This password cannot be altered, allowing
anyone with knowledge of it to gain remote access to the panel. Such
access could enable an attacker to operate the panel remotely,
potentially putting the fire panel into a non-functional state and
causing serious safety issues. |
| Use of Hard-Coded Credentials issue exists in MZK-DP300N version 1.07 and earlier, which may allow an attacker within the local network to log in to the affected device via Telnet and execute arbitrary commands. |
| A vulnerability was discovered in the storage policy for certain sets of encryption keys in the HPE Telco Network Function Virtual Orchestrator. Successful Exploitation could lead to unauthorized parties gaining access to sensitive system information. |
| A vulnerability has been found in Tenda i24, 4G03 Pro, 4G05, 4G08, G0-8G-PoE, Nova MW5G and TEG5328F up to 65.10.15.6. Affected is an unknown function of the component Shadow File. Such manipulation with the input Fireitup leads to hard-coded credentials. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. |
| There are several scripts in the web interface that are accessible via undocumented hard-coded credentials. The scripts provide access to additional administrative/debug functionality and are likely intended for debugging during development and provides an additional attack surface. |
| Forever KidsWatch Call Me KW50 R36_YDR_A3PW_GM7S_V1.0_2019_07_15_16.19.24_cob_h, and Forever KidsWatch Call Me 2 KW60 R36CW_YDE_S4_A29_2_V1.0_2023.05.24_22.49.44_cob_b have a Hardcoded password vulnerability. |
| Ubiquiti U6-LR 6.6.65 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root. NOTE: In Ubiquiti's view there is no vulnerability as the Hardcoded Password should be after setup not before. |
| A security flaw has been discovered in Apeman ID71 218.53.203.117. This vulnerability affects unknown code of the file /system/www/system.ini. The manipulation results in hard-coded credentials. The attack may be performed from remote. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way. |
| The wsc server uses a hard-coded certificate to check the authenticity of SOAP messages. An unauthenticated remote attacker can extract private keys from the Software of the affected devices. |
| Vue Vben Admin 2.10.1 allows unauthorized login to the backend due to an issue with hardcoded credentials. |
| It appears that some hardcoded keys are used for authentication to internal API. Knowing these private keys may allow attackers to bypass authentication and reach administrative interfaces. As for the affected products/models/versions, see the reference URL. |
| AMSS++ 4.7 contains an authentication bypass vulnerability that allows attackers to access administrative accounts using hardcoded credentials. Attackers can log in with the default admin username and password '1234' to gain unauthorized administrative access to the system. |
| SSL Pinning Bypass in eWeLink Some hardware products allows local ATTACKER to Decrypt TLS communication and Extract secrets to clone the device via Flash the modified firmware |
| In Eaton X303 3.5.16 - X303 3.5.17 Build 712, an attacker with network access to a XC-303 PLC can login as root over SSH. The root password is hardcoded in the firmware. NOTE: This vulnerability appears in versions that are no longer supported by Eaton. |
| Certain models of D-Link wireless routers contain an undisclosed factory testing backdoor. Unauthenticated attackers on the local area network can force the device to enable Telnet service by accessing a specific URL and can log in by using the administrator credentials obtained from analyzing the firmware. |
| Heatmiser Netmonitor 3.03 contains a hardcoded credentials vulnerability in the networkSetup.htm page with predictable admin login credentials. Attackers can access the device by using the hard-coded username 'admin' and password 'admin' in the hidden form input fields. |
| Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to disclose information such as generated power and electricity sold back to the grid stored in the product, tamper with or destroy stored or configured information in the product, or cause a Denial-of-Service (DoS) condition on the product, by using hardcoded user ID and password common to the product series obtained by exploiting CVE-2025-5022. The affected products discontinued in 2015, support ended in 2020. |
| luci-app-lucky v2.8.3 was discovered to contain hardcoded credentials. |
| Use of hard-coded credentials issue exists in ZWX-2000CSW2-HN prior to 0.3.19 and ZWX-2000CS2-HN firmware all versions. If this vulnerability is exploited, an attacker may tamper with the settings of the device by obtaining the credentials. This vulnerability is caused by an insufficient fix for CVE-2024-39838. |
| A vulnerability classified as problematic was found in Audi UTR Dashcam 2.0. Affected by this vulnerability is an unknown functionality of the component Video Stream Handler. The manipulation leads to hard-coded credentials. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. Upgrading to version 2.89 and 2.90 is able to address this issue. It is recommended to upgrade the affected component. The vendor was contacted early about these issues and acted very professional. Version 2.89 is fixing this issue for new customers and 2.90 is going to fix it for existing customers. |