Search Results (4464 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-3114 2026-04-15 N/A
Code Execution via Malicious Files: Attackers can create specially crafted files with embedded code that may execute without adequate security validation, potentially leading to system compromise. Sandbox Bypass Vulnerability: A flaw in the TERR security mechanism allows attackers to bypass sandbox restrictions, enabling the execution of untrusted code without appropriate controls.
CVE-2025-11546 2 Linux, Nec 5 Linux, Clusterpro X, Clusterpro X Singleserversafe and 2 more 2026-04-15 N/A
CLUSTERPRO X for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2 and EXPRESSCLUSTER X for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2, CLUSTERPRO X SingleServerSafe for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2, EXPRESSCLUSTER X SingleServerSafe for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2 allows an attacker sends specially crafted network packets to the product, arbitrary OS commands may be executed without authentication.
CVE-2024-8986 2026-04-15 5.5 Medium
The grafana plugin SDK bundles build metadata into the binaries it compiles; this metadata includes the repository URI for the plugin being built, as retrieved by running `git remote get-url origin`. If credentials are included in the repository URI (for instance, to allow for fetching of private dependencies), the final binary will contain the full URI, including said credentials.
CVE-2025-10870 1 Dial 1 Centrosnet 2026-04-15 N/A
SQL injection vulnerability in DIAL's CentrosNet v2.64. Allows an attacker to retrieve, create, update, and delete databases by sending POST and GET requests with the 'ultralogin' parameter in '/centrosnet/ultralogin.php'.
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2025-10363 1 Microsoft 1 Windows 2026-04-15 N/A
Deserialization of Untrusted Data vulnerability in Topal Solutions AG Topal Finanzbuchhaltung on Windows allows Remote Code Execution.This issue affects at least Topal Finanzbuchhaltung: 10.1.5.20 and is fixed in version 11.2.12.00
CVE-2024-5176 2026-04-15 N/A
Insufficiently Protected Credentials vulnerability in Baxter Welch Allyn Configuration Tool may allow Remote Services with Stolen Credentials.This issue affects Welch Allyn Configuration Tool: versions 1.9.4.1 and prior.
CVE-2025-3659 2026-04-15 N/A
Improper authentication handling was identified in a set of HTTP POST requests affecting the following product families: * Digi PortServer TS - prior to and including 82000747_AA, build date 06/17/2022 * Digi One SP/Digi One SP IA/Digi One IA - prior to and including 82000774_Z, build date 10/19/2020 * Digi One IAP – prior to and including 82000770 Z, build date 10/19/2020 A specially crafted POST request to the device’s web interface may allow an unauthenticated attacker to modify configuration settings.
CVE-2025-46274 2026-04-15 9.8 Critical
UNI-NMS-Lite uses hard-coded credentials that could allow an unauthenticated attacker to read, manipulate and create entries in the managed database.
CVE-2024-45367 1 Optigo 1 Ons-s8 Firmware 2026-04-15 9.1 Critical
The web server for ONS-S8 - Spectra Aggregation Switch includes an incomplete authentication process, which can lead to an attacker authenticating without a password.
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2025-0868 1 Arc53 1 Docsgpt 2026-04-15 N/A
A vulnerability, that could result in Remote Code Execution (RCE), has been found in DocsGPT. Due to improper parsing of JSON data using eval() an unauthorized attacker could send arbitrary Python code to be executed via /api/remote endpoint.. This issue affects DocsGPT: from 0.8.1 through 0.12.0.
CVE-2025-7426 1 Minova 1 Tta 2026-04-15 N/A
Information disclosure and exposure of authentication FTP credentials over the debug port 1604 in the MINOVA TTA service. This allows unauthenticated remote access to an active FTP account containing sensitive internal data and import structures. In environments where this FTP server is part of automated business processes (e.g. EDI or data integration), this could lead to data manipulation, extraction, or abuse.  Debug ports 1602, 1603 and 1636 also expose service architecture information and system activity logs
CVE-2011-10011 1 Webidsupport 1 Webid 2026-04-15 N/A
WeBid 1.0.2 contains a remote code injection vulnerability in the converter.php script, where unsanitized input in the to parameter of a POST request is written directly into includes/currencies.php. This allows unauthenticated attackers to inject arbitrary PHP code, resulting in persistent remote code execution when the modified script is accessed or included by the application.
CVE-2024-4826 2026-04-15 9.8 Critical
SQL injection vulnerability in Simple PHP Shopping Cart affecting version 0.9. This vulnerability could allow an attacker to retrieve all the information stored in the database by sending a specially crafted SQL query, due to the lack of proper sanitisation of the category_id parameter in the category.php file.
CVE-2025-46275 2026-04-15 9.8 Critical
WGS-80HPT-V2 and WGS-4215-8T2S are missing authentication that could allow an attacker to create an administrator account without knowing any existing credentials.
CVE-2025-3096 2026-04-15 N/A
Clinic’s Patient Management System versions 2.0 suffers from a SQL injection vulnerability in the login page.