Search Results (4474 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-4980 1 Generalbytes 1 Crypto Application Server 2026-04-15 N/A
General Bytes Crypto Application Server (CAS) beginning with version 20201208 prior to 20220531.38 (backport) and 20220725.22 (mainline) contains an authentication bypass in the admin web interface. An unauthenticated attacker could invoke the same URL used by the product's default-installation / first-admin creation page and create a new administrative account remotely. By gaining admin privileges, the attacker can change the ATM configuration resulting in redirected funds. Public vendor advisories and multiple independent writeups describe the vulnerability as a call to the page used for initial/default installation / first administration user creation; General Bytes has not publicly published the exact endpoint/parameter name. The issue was actively exploited in the wild against cloud-hosted and standalone CAS deployments (scanning exposed CAS instances on ports 7777/443), and publicly acknowledged by the General Bytes in September 2022.
CVE-2025-61778 1 Akkadotnet 1 Akka.net 2026-04-15 N/A
Akka.NET is a .NET port of the Akka project from the Scala / Java community. In all versions of Akka.Remote from v1.2.0 to v1.5.51, TLS could be enabled via our `akka.remote.dot-netty.tcp` transport and this would correctly enforce private key validation on the server-side of inbound connections. Akka.Remote, however, never asked the outbound-connecting client to present ITS certificate - therefore it's possible for untrusted parties to connect to a private key'd Akka.NET cluster and begin communicating with it without any certificate. The issue here is that for certificate-based authentication to work properly, ensuring that all members of the Akka.Remote network are secured with the same private key, Akka.Remote needed to implement mutual TLS. This was not the case before Akka.NET v1.5.52. Those who run Akka.NET inside a private network that they fully control or who were never using TLS in the first place are now affected by the bug. However, those who use TLS to secure their networks must upgrade to Akka.NET V1.5.52 or later. One patch forces "fail fast" semantics if TLS is enabled but the private key is missing or invalid. Previous versions would only check that once connection attempts occurred. The second patch, a critical fix, enforces mutual TLS (mTLS) by default, so both parties must be keyed using the same certificate. As a workaround, avoid exposing the application publicly to avoid the vulnerability having a practical impact on one's application. However, upgrading to version 1.5.52 is still recommended by the maintainers.
CVE-2013-10034 1 Kaseya 2 Kserver, Virtual System Administrator 2026-04-15 N/A
An unrestricted file upload vulnerability exists in Kaseya KServer versions prior to 6.3.0.2. The uploadImage.asp endpoint allows unauthenticated users to upload files to arbitrary paths via a crafted filename parameter in a multipart/form-data POST request. Due to the lack of authentication and input sanitation, an attacker can upload a file with an .asp extension to a web-accessible directory, which can then be invoked to execute arbitrary code with the privileges of the IUSR account. The vulnerability enables remote code execution without prior authentication and was resolved in version 6.3.0.2 by removing the vulnerable uploadImage.asp endpoint.
CVE-2020-37027 1 Midgetspy 1 Sickbeard 2026-04-15 9.8 Critical
Sickbeard alpha contains a remote command injection vulnerability that allows unauthenticated attackers to execute arbitrary commands through the extra scripts configuration. Attackers can set malicious commands in the extra scripts field and trigger processing to execute remote code on the vulnerable Sickbeard installation.
CVE-2020-37052 1 Ubiquiti 1 Aircontrol 2026-04-15 9.8 Critical
AirControl 1.4.2 contains a pre-authentication remote code execution vulnerability that allows unauthenticated attackers to execute arbitrary system commands through malicious Java expression injection. Attackers can exploit the /.seam endpoint by crafting a specially constructed URL with embedded Java expressions to run commands with the application's system privileges.
CVE-2025-62691 2 Intercom, Microsoft 2 Malion, Windows 2026-04-15 N/A
Security Point (Windows) of MaLion and MaLionCloud contains a stack-based buffer overflow vulnerability in processing HTTP headers. Receiving a specially crafted request from a remote unauthenticated attacker could lead to arbitrary code execution with SYSTEM privilege.
CVE-2025-6950 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Use of Hard-coded Credentials vulnerability has been identified in Moxa’s network security appliances and routers. The system employs a hard-coded secret key to sign JSON Web Tokens (JWT) used for authentication. This insecure implementation allows an unauthenticated attacker to forge valid tokens, thereby bypassing authentication controls and impersonating any user. Exploitation of this vulnerability can result in complete system compromise, enabling unauthorized access, data theft, and full administrative control over the affected device. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems.
CVE-2025-7353 1 Rockwellautomation 1 Controllogix 2026-04-15 N/A
A security issue exists due to the web-based debugger agent enabled on Rockwell Automation ControlLogix® Ethernet Modules. If a specific IP address is used to connect to the WDB agent, it can allow remote attackers to perform memory dumps, modify memory, and control execution flow.
CVE-2025-4041 2026-04-15 N/A
In Optigo Networks ONS NC600 versions 4.2.1-084 through 4.7.2-330, an attacker could connect with the device's ssh server and utilize the system's components to perform OS command executions.
CVE-2025-34102 2026-04-15 N/A
A remote code execution vulnerability exists in CryptoLog (PHP version, discontinued since 2009) due to a chained exploitation of SQL injection and command injection vulnerabilities. An unauthenticated attacker can gain shell access as the web server user by first exploiting a SQL injection flaw in login.php to bypass authentication, followed by command injection in logshares_ajax.php to execute arbitrary operating system commands. The login bypass is achieved by submitting crafted SQL via the user POST parameter. Once authenticated, the attacker can abuse the lsid POST parameter in the logshares_ajax.php endpoint to inject and execute a command using $(...) syntax, resulting in code execution under the web context. This exploitation path does not exist in the ASP.NET version of CryptoLog released since 2009.
CVE-2025-11043 1 Br-automation 2 Automation Studio, Studio 2026-04-15 7.4 High
An Improper Certificate Validation vulnerability in the OPC-UA client and ANSL over TLS client used in Automation Studio versions before 6.5 could allow an unauthenticated attacker on the network to position themselves to intercept and interfere with data exchanges.
CVE-2025-40800 1 Siemens 6 Comos, Nx, Simcenter 3d and 3 more 2026-04-15 7.4 High
A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), NX V2412 (All versions < V2412.8700), NX V2506 (All versions < V2506.6000), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Solid Edge SE2025 (All versions < V225.0 Update 10), Solid Edge SE2026 (All versions < V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.
CVE-2010-20112 2026-04-15 N/A
Amlib’s NetOpacs webquery.dll contains a stack-based buffer overflow vulnerability triggered by improper handling of HTTP GET parameters. Specifically, the application fails to enforce bounds on input supplied to the app parameter, allowing excessive data to overwrite memory structures including the Structured Exception Handler (SEH). Additionally, malformed parameter names followed by an equals sign may result in unintended control flow behavior. This vulnerability is exposed through IIS and affects legacy Windows deployments
CVE-2025-15346 1 Wolfssl 1 Wolfssl 2026-04-15 N/A
A vulnerability in the handling of verify_mode = CERT_REQUIRED in the wolfssl Python package (wolfssl-py) causes client certificate requirements to not be fully enforced.  Because the WOLFSSL_VERIFY_FAIL_IF_NO_PEER_CERT flag was not included, the behavior effectively matched CERT_OPTIONAL: a peer certificate was verified if presented, but connections were incorrectly authenticated when no client certificate was provided.  This results in improper authentication, allowing attackers to bypass mutual TLS (mTLS) client authentication by omitting a client certificate during the TLS handshake.  The issue affects versions up to and including 5.8.2.
CVE-2025-10910 2026-04-15 N/A
A flaw in the binding process of Govee’s cloud platform and devices allows a remote attacker to bind an existing, online Govee device to the attacker’s account, resulting in full control of the device and removal of the device from its legitimate owner’s account. The server‑side API allows device association using a set of identifiers: "device", "sku", "type", and a client‑computed "value", that are not cryptographically bound to a secret originating from the device itself. The vulnerability has been verified for the Govee H6056 - lamp device in firmware version 1.08.13, but may affect also other Govee cloud‑connected devices. The vendor is investigating other potentially affected models. The vendor has deployed server-side security enhancements and automatic firmware updates for model H6056. Most of H6056 devices have been successfully patched through automatic updates. Remaining H6056 users with upgradeable hardware versions must manually update firmware through the Govee Home app while keeping their device WiFi-connected. Users should open the Govee Home app, tap their H6056 device card to enter the device details page, tap the settings icon in the upper right corner, navigate to Device Information section (Firmware Version), and tap the Update button to install the security patch immediately. Govee H6056 devices with hardware versions 1.00.10 or 1.00.11 cannot receive firmware update due to hardware limitations.
CVE-2010-20115 2 Arcane Software, Microsoft 2 Vermillion Ftp Daemon, Windows 2026-04-15 N/A
Arcane Software’s Vermillion FTP Daemon (vftpd) versions up to and including 1.31 contains a memory corruption vulnerability triggered by a malformed FTP PORT command. The flaw arises from an out-of-bounds array access during input parsing, allowing an attacker to manipulate stack memory and potentially execute arbitrary code. Exploitation requires direct access to the FTP service and is constrained by a single execution attempt if the daemon is installed as a Windows service.
CVE-2025-24480 2026-04-15 N/A
A Remote Code Execution Vulnerability exists in the product and version listed above. The vulnerability is due to lack of input sanitation and could allow a remote attacker to run commands or code as a high privileged user.
CVE-2025-34055 2026-04-15 N/A
An OS command injection vulnerability exists in AVTECH DVR, NVR, and IP camera devices within the adcommand.cgi endpoint, which interfaces with the ActionD daemon. Authenticated users can invoke the DoShellCmd operation, passing arbitrary input via the strCmd parameter. This input is executed directly by the system shell without sanitation allowing attackers to execute commands as the root user.
CVE-2025-34056 2026-04-15 N/A
An OS command injection vulnerability exists in AVTECH IP camera, DVR, and NVR devices via the PwdGrp.cgi endpoint, which handles user and group management operations. Authenticated users can supply input through the pwd or grp parameters, which are directly embedded into system commands without proper sanitation. This allows for the execution of arbitrary shell commands with root privileges.
CVE-2025-4009 2026-04-15 N/A
The Evertz SDVN 3080ipx-10G is a High Bandwidth Ethernet Switching Fabric for Video Application. This device exposes a web management interface on port 80. This web management interface can be used by administrators to control product features, setup network switching, and register license among other features. The application has been developed in PHP with the webEASY SDK, also named ‘ewb’ by Evertz. This web interface has two endpoints that are vulnerable to arbitrary command injection (CVE-2025-4009, CVE-2025-10364) and the authentication mechanism has a flaw leading to authentication bypass (CVE-2025-10365). CVE-2025-4009 covers the command injection in feature-transfer-import.php CVE-2025-10364 covers the command injection in feature-transfer-export.php Remote unauthenticated attackers can gain arbitrary command execution with elevated privileges ( root ) on affected devices. This level of access could lead to serious business impact such as the interruption of media streaming, modification of media being streamed, alteration of closed captions being generated, among others.