Export limit exceeded: 409713 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (759 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2026-28794 | 2 Middleapi, Orpc | 2 Orpc, Orpc | 2026-04-16 | 9.8 Critical |
| oRPC is an tool that helps build APIs that are end-to-end type-safe and adhere to OpenAPI standards. Prior to version 1.13.6, a prototype pollution vulnerability exists in the RPC JSON deserializer of the @orpc/client package. The vulnerability allows unauthenticated, remote attackers to inject arbitrary properties into the global Object.prototype. Because this pollution persists for the lifetime of the Node.js process and affects all objects, it can lead to severe security breaches, including authentication bypass, denial of service, and potentially Remote Code Execution. This issue has been patched in version 1.13.6. | ||||
| CVE-2026-3201 | 1 Wireshark | 1 Wireshark | 2026-04-16 | 4.7 Medium |
| USB HID protocol dissector memory exhaustion in Wireshark 4.6.0 to 4.6.3 and 4.4.0 to 4.4.13 allows denial of service | ||||
| CVE-2026-21528 | 1 Microsoft | 1 Azure Iot Explorer | 2026-04-15 | 6.5 Medium |
| Binding to an unrestricted ip address in Azure IoT Explorer allows an unauthorized attacker to disclose information over a network. | ||||
| CVE-2023-50738 | 1 Lexmark | 1 Printer Firmware | 2026-04-15 | 4.3 Medium |
| A new feature to prevent Firmware downgrades was recently added to some Lexmark products. A method to override this downgrade protection has been identified. | ||||
| CVE-2025-31929 | 2026-04-15 | 4.2 Medium | ||
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code. | ||||
| CVE-2024-36583 | 1 Byondreal | 1 Accessor | 2026-04-15 | 8.1 High |
| A Prototype Pollution issue in byondreal accessor <= 1.0.0 allows an attacker to execute arbitrary code via @byondreal/accessor/index. | ||||
| CVE-2024-36580 | 2026-04-15 | 9.8 Critical | ||
| A Prototype Pollution issue in cdr0 sg 1.0.10 allows an attacker to execute arbitrary code. | ||||
| CVE-2025-62517 | 1 Rollbar | 1 Rollbar | 2026-04-15 | 5.9 Medium |
| Rollbar.js offers error tracking and logging from Javascript to Rollbar. In versions before 2.26.5 and from 3.0.0-alpha1 to before 3.0.0-beta5, there is a prototype pollution vulnerability in merge(). If application code calls rollbar.configure() with untrusted input, prototype pollution is possible. This issue has been fixed in versions 2.26.5 and 3.0.0-beta5. A workaround involves ensuring that values passed to rollbar.configure() do not contain untrusted input. | ||||
| CVE-2024-36577 | 1 Apphp | 1 Apphp Js-object-resolver | 2026-04-15 | 8.3 High |
| apphp js-object-resolver < 3.1.1 is vulnerable to Prototype Pollution via Module.setNestedProperty. | ||||
| CVE-2024-36574 | 1 Amirziai | 1 Flatten Json | 2026-04-15 | 6.3 Medium |
| A Prototype Pollution issue in flatten-json 1.0.1 allows an attacker to execute arbitrary code via module.exports.unflattenJSON (flatten-json/index.js:42) | ||||
| CVE-2025-57352 | 2026-04-15 | 5.3 Medium | ||
| A vulnerability exists in the 'min-document' package prior to version 2.19.0, stemming from improper handling of namespace operations in the removeAttributeNS method. By processing malicious input involving the __proto__ property, an attacker can manipulate the prototype chain of JavaScript objects, leading to denial of service or arbitrary code execution. This issue arises from insufficient validation of attribute namespace removal operations, allowing unintended modification of critical object prototypes. The vulnerability remains unaddressed in the latest available version. | ||||
| CVE-2024-14020 | 1 Carboneio | 1 Carbone | 2026-04-15 | 5 Medium |
| A weakness has been identified in carboneio carbone up to fbcd349077ad0e8748be73eab2a82ea92b6f8a7e. This impacts an unknown function of the file lib/input.js of the component Formatter Handler. Executing a manipulation can lead to improperly controlled modification of object prototype attributes. The attack can be launched remotely. This attack is characterized by high complexity. The exploitability is said to be difficult. Upgrading to version 3.5.6 will fix this issue. This patch is called 04f9feb24bfca23567706392f9ad2c53bbe4134e. You should upgrade the affected component. A successful exploitation can "only occur if the parent NodeJS application has the same security issue". | ||||
| CVE-2024-24293 | 1 Miguelcastillo | 1 Bit-loader | 2026-04-15 | 8.8 High |
| A Prototype Pollution issue in MiguelCastillo @bit/loader v.10.0.3 allows an attacker to execute arbitrary code via the M function e argument in index.js. | ||||
| CVE-2025-8101 | 1 Linkify | 1 Linkify | 2026-04-15 | 8.6 High |
| Improperly Controlled Modification of Object Prototype Attributes ('Prototype Pollution') vulnerability in Linkify (linkifyjs) allows XSS Targeting HTML Attributes and Manipulating User-Controlled Variables.This issue affects Linkify: from 4.3.1 before 4.3.2. | ||||
| CVE-2025-27597 | 1 Intlify | 1 Vue-i18n | 2026-04-15 | N/A |
| Vue I18n is the internationalization plugin for Vue.js. @intlify/message-resolver and @intlify/vue-i18n-core are vulnerable to Prototype Pollution through the entry function: handleFlatJson. An attacker can supply a payload with Object.prototype setter to introduce or modify properties within the global prototype chain, causing denial of service (DoS) a the minimum consequence. Moreover, the consequences of this vulnerability can escalate to other injection-based attacks, depending on how the library integrates within the application. For instance, if the polluted property propagates to sensitive Node.js APIs (e.g., exec, eval), it could enable an attacker to execute arbitrary commands within the application's context. | ||||
| CVE-2024-32866 | 1 Edmundhung | 1 Conform | 2026-04-15 | 8.6 High |
| Conform, a type-safe form validation library, allows the parsing of nested objects in the form of `object.property`. Due to an improper implementation of this feature in versions prior to 1.1.1, an attacker can exploit the feature to trigger prototype pollution by passing a crafted input to `parseWith...` functions. Applications that use conform for server-side validation of form data or URL parameters are affected by this vulnerability. Version 1.1.1 contains a patch for the issue. | ||||
| CVE-2024-39013 | 1 2o3t | 1 2o3t-utility | 2026-04-15 | 9.8 Critical |
| 2o3t-utility v0.1.2 was discovered to contain a prototype pollution via the function extend. This vulnerability allows attackers to execute arbitrary code or cause a Denial of Service (DoS) via injecting arbitrary properties. | ||||
| CVE-2024-36573 | 1 Almela | 1 Obx | 2026-04-15 | 9.8 Critical |
| almela obx before v.0.0.4 has a Prototype Pollution issue which allows arbitrary code execution via the obx/build/index.js:656), reduce (@almela/obx/build/index.js:470), Object.set (obx/build/index.js:269) component. | ||||
| CVE-2025-11538 | 1 Redhat | 1 Build Keycloak | 2026-04-15 | 6.8 Medium |
| A vulnerability exists in Keycloak's server distribution where enabling debug mode (--debug <port>) insecurely defaults to binding the Java Debug Wire Protocol (JDWP) port to all network interfaces (0.0.0.0). This exposes the debug port to the local network, allowing an attacker on the same network segment to attach a remote debugger and achieve remote code execution within the Keycloak Java virtual machine. | ||||
| CVE-2024-38992 | 1 Airvert Thuan | 1 Frappejs | 2026-04-15 | 8.8 High |
| airvertco frappejs v0.0.11 was discovered to contain a prototype pollution via the function registerView. This vulnerability allows attackers to execute arbitrary code or cause a Denial of Service (DoS) via injecting arbitrary properties. | ||||