Search Results (691 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-8524 2 Boquan, Google 2 Dotwalle App, Android 2026-04-15 5.3 Medium
A vulnerability was found in Boquan DotWallet App 2.15.2 on Android and classified as problematic. Affected by this issue is some unknown functionality of the file AndroidManifest.xml of the component com.boquanhash.dotwallet. The manipulation leads to improper export of android application components. The attack needs to be approached locally. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-46635 2026-04-15 5.9 Medium
An issue in the API endpoint /AccountMaster/GetCurrentUserInfo of INROAD before v202402060 allows attackers to access sensitive information via a crafted payload to the UserNameOrPhoneNumber parameter.
CVE-2024-49201 2026-04-15 4.3 Medium
Keyfactor Remote File Orchestrator (aka remote-file-orchestrator) 2.8 before 2.8.1 allows Information Disclosure: sensitive information could be exposed at the debug logging level.
CVE-2024-3479 2026-04-15 2.8 Low
An improper export vulnerability was reported in the Motorola Enterprise MotoDpms Provider (com.motorola.server.enterprise.MotoDpmsProvider) that could allow a local attacker to read local data.
CVE-2024-36252 2026-04-15 6.3 Medium
Improper restriction of communication channel to intended endpoints issue exists in Ricoh Streamline NX PC Client ver.3.6.x and earlier. If this vulnerability is exploited, arbitrary code may be executed on the PC where the product is installed.
CVE-2024-52288 2026-04-15 5.1 Medium
libosdp is an implementation of IEC 60839-11-5 OSDP (Open Supervised Device Protocol) and provides a C library with support for C++, Rust and Python3. In affected versions an unexpected `REPLY_CCRYPT` or `REPLY_RMAC_I` may be introduced into an active stream when they should not be. Once RMAC_I message can be sent during a session, attacker with MITM access to the communication may intercept the original RMAC_I reply and save it. While the session continues, the attacker will record all of the replies and save them, till capturing the message to be replied (can be detected by ID, length or time based on inspection of visual activity next to the reader) Once attacker captures a session with the message to be replayed, he stops resetting the connection and waits for signal to perform the replay to of the PD to CP message (ex: by signaling remotely to the MIMT device or setting a specific timing). In order to replay, the attacker will craft a specific RMAC_I message in the proper seq of the execution, which will result in reverting the RMAC to the beginning of the session. At that phase - attacker can replay all the messages from the beginning of the session. This issue has been addressed in commit `298576d9` which is included in release version 3.0.0. Users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2024-37728 1 Officeweb365 1 Officeweb365 2026-04-15 7.5 High
Arbitrary File Read vulnerability in Xi'an Daxi Information Technology Co., Ltd OfficeWeb365 v.7.18.23.0 and v8.6.1.0 allows a remote attacker to obtain sensitive information via the "Pic/Indexes" interface
CVE-2024-38496 1 Broadcom 1 Symantec Privileged Access Management 2026-04-15 N/A
The vulnerability allows a malicious low-privileged PAM user to access information about other PAM users and their group memberships.
CVE-2024-37654 1 Bas-ip 29 Aa-07bd, Aa-07bdi, Av-01bd and 26 more 2026-04-15 6.1 Medium
An issue in BAS-IP AV-01D, AV-01MD, AV-01MFD, AV-01ED, AV-01KD, AV-01BD, AV-01KBD, AV-02D, AV-02IDE, AV-02IDR, AV-02IPD, AV-02FDE, AV-02FDR, AV-03D, AV-03BD, AV-04AFD, AV-04ASD, AV-04FD, AV-04SD, AV-05FD, AV-05SD, AA-07BD, AA-07BDI, BA-04BD, BA-04MD, BA-08BD, BA-08MD, BA-12BD, BA-12MD, CR-02BD before 3.9.2 allows a remote attacker to obtain sensitive information via a crafted HTTP GET request.
CVE-2024-39339 1 Globalsuzuki 1 Smartplay Headunit Firmware 2026-04-15 7.5 High
A vulnerability has been discovered in all versions of Smartplay headunits, which are widely used in Suzuki and Toyota cars. This misconfiguration can lead to information disclosure, leaking sensitive details such as diagnostic log traces, system logs, headunit passwords, and personally identifiable information (PII). The exposure of such information may have serious implications for user privacy and system integrity.
CVE-2021-42718 1 Replicated 1 Replicated Classic 2026-04-15 4.9 Medium
Information Disclosure in API in Replicated Replicated Classic versions prior to 2.53.1 on all platforms allows authenticated users with Admin Console access to retrieve sensitive data, including application secrets, via accessing container definitions with environment variables through the Admin Console API on port 8800. This CVE was originally reserved in 2021 and later publicly disclosed by Replicated on their website on 21 October 2021. However, it mistakenly remained in the Reserved But Public (RBP) status with the CVE Numbering Authority (CNA). Please note that this product reached its end of life on 31 December 2024. Publishing this CVE with the CNA was required to comply with CNA rules, despite the fact that the issue was disclosed and fixed four years ago, and the affected product is no longer supported as of 2024. Summary of VulnerabilityThis advisory discloses a low severity security vulnerability in the versions of Replicated Classic listed above (“Affected Replicated Classic Versions”) DescriptionReplicated Classic versions prior to 2.53.1 have an authenticated API from the Replicated Admin Console that may expose sensitive data including application secrets, depending on how the application manifests are written. A user with valid credentials and access to the Admin Console port (8800) on the Replicated Classic server can retrieve container definitions including environment variables which may contain passwords and other secrets depending on how the application is configured. This data is shared over authenticated sessions to the Admin Console only, and was never displayed or used in the application processing. To remediate this issue, we removed the sensitive data from the API, sending only the data to the Admin Console that was needed. TimelineThis issue was discovered during a security review on 16 September 2021. Patched versions were released on 23 September 2021. This advisory was published on 21 October 2021. The CVE Numbering Authority (CNA) notified Replicated on 23 January 2025 that the CVE was still in Reserved But Public (RBP) status. Upon discovering the oversight in updating the status to published with the CNA, Replicated submitted the updated report on the same day, 23 January 2025.
CVE-2024-56113 2026-04-15 7.5 High
Smart Toilet Lab - Motius 1.3.11 is running with debug mode turned on (DEBUG = True) and exposing sensitive information defined in Django settings file through verbose error page.
CVE-2024-48939 1 Paxton-access 1 Net2 2026-04-15 7.5 High
Insufficient validation performed on the REST API License file in Paxton Net2 before 6.07.14023.5015 (SR4) enables use of the REST API with an invalid License File. Attackers may be able to retrieve access-log data.
CVE-2024-56972 2026-04-15 6.5 Medium
An issue in Midea Group Co., Ltd Midea Home iOS 9.3.12 allows attackers to access sensitive user information via supplying a crafted link.
CVE-2024-56953 2026-04-15 6.5 Medium
An issue in Baidu (China) Co Ltd Baidu Input Method (iOS version) v12.6.13 allows attackers to access user information via supplying a crafted link.
CVE-2025-33176 1 Nvidia 1 Runai 2026-04-15 6.2 Medium
NVIDIA RunAI for all platforms contains a vulnerability where a user could cause an improper restriction of communications channels on an adjacent network. A successful exploit of this vulnerability might lead to escalation of privileges, data tampering, and information disclosure.
CVE-2024-56948 2026-04-15 6.5 Medium
An issue in KuGou Technology CO. LTD KuGou Music iOS v20.0.0 allows attackers to access sensitive user information via supplying a crafted link.
CVE-2025-12357 2 Iec, Iso 15118-2 Network And Application Protocol Requirements 2 Ev Car Chargers, Ev Car Chargers 2026-04-15 6.3 Medium
By manipulating the Signal Level Attenuation Characterization (SLAC) protocol with spoofed measurements, an attacker can stage a man-in-the-middle attack between an electric vehicle and chargers that comply with the ISO 15118-2 part. This vulnerability may be exploitable wirelessly, within close proximity, via electromagnetic induction.
CVE-2024-13954 1 Abb 3 Aspect Enterprise, Matrix Series, Nexus Series 2026-04-15 6.5 Medium
Serialized configuration information may be disclosed during device commissioning while using ASPECT's configuration toolsetThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*.
CVE-2025-31144 2026-04-15 N/A
Quick Agent V3 and Quick Agent V2 contain an issue with improper restriction of communication channel to intended endpoints. If exploited, a remote unauthenticated attacker may attempt to log in to an arbitrary host via Windows system where the product is running.